View Categories

Shelly Qubino Wave 1PM

Device Identification #

Device: Wave 1PM
AU Part number/Ordering Code: QNSW-001P16AU
Z-Wave Product type ID: 0x0002
Z-Wave Product ID: 0x0084
Z-Wave Manufacturer: Shelly Europe Ltd.
Z-Wave Manufacturer ID: 0x0460

Terminology #

  • Device – In this document, the term “Device” is used to refer to the Shelly Qubino device that is a subject of this guide.
  • Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.
  • S button – The Z-Wave® Service button, located on Z-Wave® devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term “S button” is used in this document.

Short description #

The Device is a single product that enables the control of the on/off function for one electrical device such as bulb, ceiling fan, IR heater. It measures power consumption of the connected device. The Device is compatible with switches (default) and push-buttons.

Switch connected to input terminal SW (SW1) #

If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O (O1) to the opposite state – ON, OFF, ON, etc.

  • Change switch position once: Change the state of the output state O (O1) to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)
  • Change switch position twice: If the delay between first in second click is less then 500ms, this is interpreted as Change switch position twice. Send command to the associated devices (dimmers, shutters,….) in associated groups 2 and 3 (check chapter Z-Wave Association)

Main applications #

  • Residential
  • MDU (Multi Dwelling Units – apartments, condominiums, hotels, etc.)
  • Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
  • Government/municipal
  • University/college

Integrations #

Shelly Qubino Wave devices are developed on the world’s leading technology for smart homes – Z-Wave.

This means Shelly Qubino Wave works with all certified gateways supporting Z-Wave communication protocol.

To make sure the functions of Shelly Qubino Wave products are supported on your gateway, we are regularly executing compatibility tests of our devices with different Z-Wave gateways.

Simplified internal schematics #

Device electrical interfaces #

Inputs #

  • 1 switch/button input on screw terminal
  • 5 power supply inputs on screw terminals: 2 N and 3 L

Outputs #

  • 1 relay output with power measurement on screw terminal

Connectivity #

Z-Wave – Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security

Safety features #

Overheat protection #

  • switch off its own relay
  • sends the Notification Report to the Gateway (Overheat detected)
  • the led lights react as specified above (check blinking mode for Overheat detected)

Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.

NOTE: The Overheat protection is always active and cannot be disabled.
Additional description above under chapter Notification for Overheat detected.

Over-current Protection #

Device has internal Over-current protection. If the current exceeds 16A+10% (Max switching current +10%) for more than 5s, the Device will:

  • switch off its own relay
  • sends the Notification Report to the Gateway (Over-current detected)
  • the led lights react as specified above (check blinking mode for Over-current detected)

Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.

NOTE: The Over-current protection is always active and cannot be disabled.
Additional description above under chapter Notification for Over-current detected.

Supported load types #

  • Resistive (incandescent bulbs, heating devices)
  • Capacitive (capacitor banks, electronic equipment, motor start capacitors)
  • Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)

User interface #

S button and operating modes #

  1. Normal mode
  2. Setting in progress mode
  3. Setting mode (with S button)
    • Settings mode is required to start desired procedure for example: adding (inclusion), removing (exclusion), factory reset etc. It has a limited time of operation. After the procedure in Setting mode is concluded, the Device goes automatically into Normal mode.
    • Entering to Setting mode:
      • Quickly press and hold the S button on the Device until the LED turns solid blue
      • An additional quick press on the S button means menu change in infinite loop
      • Menu LED status has a timeout of 10s before entering again into Normal state

S button’s functions #

  • Manually adding the Device to a Z-Wave network
  • Manually removing the Device from a Z-Wave network
  • Factory Reset the Device

Specifications #

Power supply110-240 V AC, 50/60 Hz
Power consumption< 0.3 W
Power measurement (W)Yes
Max. switching voltage AC240 V
Max. switching current AC16 A
Overheating protectionYes
Overload protectionYes
DistanceUp to 40 m indoors (131 ft.) (depends on local condition)
Z-Wave® repeaterYes
CPUZ-Wave® S800
Z-Wave® frequency bands919,8 MHz
Maximum radio frequency power transmitted in frequency band(s)< 25 mW
Size (H x W x D)37x42x16 ±0.5 mm / 1.46×1.65×0.63 ±0.02 in
Weight27 g / 0.95 oz.
MountingWall console
Screw terminals max. torque0.4 Nm / 3.5 lbin
Conductor cross section0.5 to 1.5 mm² / 20 to 16 AWG
Conductor stripped length5 to 6 mm / 0.20 to 0.24 in
Shell materialPlastic
ColourRed
Ambient temperature-20°C to 40°C / -5°F to 105°F
Humidity30% to 70% RH
Max. altitude2000 m / 6562 ft.

Basic wiring diagram #

Legend #

Enlarges the table by opening it in a full screen dialogOpen

TerminalsWires
NNeutral terminalNNeutral wire
LLive terminal (110–240 V AC)LLive (110 – 240 VAC) wire
SWSwitch/push-button input terminal (controlling O)
OLoad circuit output terminal

Leave a Reply